Moment-resisting Connections
Members Inputs
All references to EN 1995-1-1:2004
unless otherwise stated.
This refers to a connection of two or three members on the same axis under a force and a moment, according to Section 8
.
Double shear
Select if the connection if the fasteners operate in single or double shear.
In single shear, the connection consists of the two members defined under Member 1 and Member 2 below.
In double shear, the connection consists of three members, two identical members defined under Member 1 below, and a member defined as Member 2 below in the middle.
Member 1
Data for the first member.
Material
The material of the first member.
Teretron supports both timber-to-timber and timber-to-steel connections. Steel-to-steel connections are not supported.
Timber Type
The timber type of the cross-section. See the timber database section for the types supported by Teretron.
Characteristic density ρk,1
The characteristic density of the timber of the first member ρk, in kg/m3.
It is required in certain types of plywood where the relevant standards do not provide a value.
Depth h1
The depth of the cross-section of the first member in a single shear connection, or the first and third members in a double shear connection, in mm.
Width b1
The width of the cross-section of the first member in a single shear connection, or the first and third members in a double shear connection, in mm.
Angle φ1
The angle φ1 of the x-x axis of the first member with the plane, in degrees.
End
Defines if the connection is near the ends of the member.
The user can select from the following:
- ○ Continuous for a connection that is not near the end of the member.
- ○ Both sides for a connection that is near both ends of the member, at an equal distance from them.
- ○ Left for a connection that is near the left hand-side end of the member.
- ○ Right for a connection that is near the right hand-side end of the member.
End distance l1
The distance between the centre of gravity of the connection and the end of the member, in mm.
Member 2
Data for the second member.
Material
The material of the second member.
Teretron supports both timber-to-timber and timber-to-steel connections. Steel-to-steel connections are not supported.
Timber Type
The timber type of the cross-section. See the timber database section for the types supported by Teretron.
Characteristic density ρk,2
The characteristic density of the timber of the second member ρk, in kg/m3.
It is required in certain types of plywood where the relevant standards do not provide a value.
Depth h2
The depth of the cross-section of the second member, in mm.
Width b2
The width of the cross-section of the second member, in mm.
Angle φ2
The angle φ2 of the x-x axis of the second member with the plane, in degrees.
End
Defines if the connection is near the ends of the member.
The user can select from the following:
- ○ Continuous for a connection that is not near the end of the member.
- ○ Both sides for a connection that is near both ends of the member, at an equal distance from them.
- ○ Left for a connection that is near the left hand-side end of the member.
- ○ Right for a connection that is near the right hand-side end of the member.
End distance l2